HPLC/UHPLC
HPLC/UHPLCS6000 HPLC
S6000 HPLC
Acchrom-tech, starting from the needs of users, analyzed the development history of liquid chromatography in the past 30 years, and based on the current advanced chromatography theory and new design i 咨询产品信息Pump System
■ Double ball series check valve
Pressure is more stable and the solvent is tolerated better.
■ HFM high-frequency mixing mode
Improve the mixing accuracy of the mobiles phase by increasing the proportional valve switching frequency.
The solvent is fully mixed without bigger mixer, which greatly reduces the system volume (<700ul) and improves the baseline noise caused by poor mixing.
■ High-speed feedback, real-time control & special cam curve design
Through the pressure monitoring of the system in real time, adjust the motor speed, equipped with the special curve cam drive, to ensure the stable flow, and effectively reduce the infusion pulsation. Stable flow pumping of 0.001-10.000 ml/min.
Sample Management System
■ Sample carryover can reach <0.003%
Innovative inlet design to achieve long life seal and nearly zero dead volume.
Special flush flow path and rinse fluid to adequately flush the entire injection system.
■ Temperature-controlled automatic sampler
The temperature control uses the automatic injection sample detector temperature control module to realize the effective temperature control of 1℃ ~45℃. The temperature of the sampler can be accurately stabilized at the set value to ensure the stability of the temperature-sensitive samples.
Column Management System
■ creative high-capacity design
A
300-mm column can be placed
Built-in
column switching valve or functional valve is optional
■ Heating / cooling mode:
Peltier
Temperature setting range: 1~90℃
Heating / cooling bidirectional capability
by powerful Peltier, temperature control is faster, more accurate, more stable.
■ mobiles Phase preheating function
The mobiles phase is pre-heated before
entering the column, which reduces the interference to the temperature
environment in the column and ensures excellent peak shape symmetry and
sharpness and reproducibility.
Rich Variety of Excellent Performance Detector
■ A variety of detectors are available
Provide complete detection techniques including UV, DAD, FLR, RI, ELS detectors.
Specifications
Mixing Mode:
Quaternary
FLow rate range:
0.001-10.000 ml/min
Max operate pressure:
45MPa / 62MPa
Max Injection volume:
100ul,can be expended to 1000ul
Temp. Range:
1-45℃ (Room Temp.-24℃-- Room Temp. +20℃)
Injector Capacity:
120 2ml vials, 96-well plates compatible
Column Oven Temp.:
1-90℃(Room Temp. -24℃--Room Temp. +65℃)
Column Switch:
Optional
Max Column Capacity:
300mm column, 3 columns
DAD detector
1024 diodes
Wavelength Cal.
Built-in Hg lamp calibrate
Max Sampling rate:
160Hz
Reference Wavelength:
Independent mode, different reference wavelength can be set for each channel
Thank you for your attention and trust in Acchrom Tech products. If you have any questions or abnormal situations with the products during browsing the website, please leave a message or call our company.
Customer Service Hotline :400-108-7908,