HPLC/UHPLC
HPLC/UHPLCS3000 HPLC
S3000 HPLC
The S3000 high-performance liquid chromatography instrument adheres to Huapu's consistent development philosophy of high-performance liquid chromatography instruments. Based on further understanding u 咨询产品信息
The pump system realizes the high precision mixing of the four-element gradient system, reduces the infusion pulsation, and ensures the accuracy of infusion and the stability of use.
■ Special curve-shaped cam design
Special curve cam drive plunger makes the infusion more stable and lower pulsation.
■ High-speed feedback, real-time control
Through the real-time pressure monitoring of the system, adjust the motor speed, with special, curve cam drive, and further reduce the flow stability.
■ Strcade inlet and outlet check valve design
Series
two-stage pump head infusion is adopted, and the pump head inlet and outlet
valves can ensure the infusion stability to a large extent and reduce the
pulsation of the pump system.
The automatic injection system adopts innovative injection system design and advanced direct injection method, with a new fit design, lower residue, stable reproduction, and fast injection to meet the high throughput requirements.
■ Direct injection approach with low residues
Direct injection, as part of the flow path, ensures that all the samples enter the analysis system, avoids the waste of the samples, reduces the residue of the samples in the injection system, and ensures the reproducibility of high precision injection
■ High-precision sample injection control
The new high-precision syringe drive unit is used to achieve excellent injection volume reproducibility and reliability of analysis results.
Column Oven
The column temperature box adopts the temperature control unit and specially designed preheating function to ensure the sharp, symmetrical and reproducible chromatography peak.
■ Air circulation + preheating mode
The
mobiles phase is pre-heated before entering the column to reduce the interference
to the temperature in the column.
The air inside the column temperature box is always circulating to ensure that the ambient temperature around the column is constant;
■ Vertical column temperature box design
Vertical column temperature box can be placed into a larger column: compatible with 300mm long column, can be put up to 3 long chromatcolumns.
■ The built-in switching valve can be configured
Reserved built-in switching valve installation valve position to meet the requirements of column switching or multi-dimensional chromatography application.
UV-detector
The UV detector, using high-quality optical unit and optimized optical path design, can provide higher sensitivity and meet the analysis of trace and trace samples.
■ Quality optical unit
The body of the optical bench adopts the overall primary forming process to ensure the stable operation of the optical device under different temperature and humidity environments.
■ Dual beam design
Using a dual beam design, the reference beam alone can effectively improve the baseline drift due to the aging of the optical components.
Specification:
Gradient mode: |
Quaternary gradient |
Flow rate range: |
0.001-10.000 ml/min |
Maximum pressure: |
40MPa |
Max Injection volume: |
100ul, can be extended to 1000ul |
Sampler Temperature: |
1-45℃ |
Sampler capacity: |
120-bit 2ml vial, compatible with 96-well plates |
Column temperature box temperature: |
Room temperature +5℃-65℃ |
Automatic column switching valve: |
Built-in type, optional |
Column capacity: |
Max 300mm long columns, up to 3 columns |
UV detector |
Dual beam design |
wavelength self-calibration: |
Built-in mercury lamp calibration |
wavelength coverage: |
190nm--700nm |
Maximum sampling frequency: |
100Hz |
Thank you for your attention and trust in Acchrom Tech products. If you have any questions or abnormal situations with the products during browsing the website, please leave a message or call our company.
Customer Service Hotline :400-108-7908,
We will contact you as soon as possible and wish you and your family happiness and health!